Fitting a Bathroom Extractor Fan: Part F, Ducting and Timers
Fitting a bathroom extractor fan the right way: the Part F extract rate, rigid ducting with a fall, a run-on timer, and the wiring that needs a registered electrician.
A bathroom without an extractor fan will grow mould within one winter, usually on the ceiling above the bath and behind the wardrobe. The fan itself is a cheap fix. Getting it to work properly is where most DIY jobs go wrong: the duct leaks, the fan is wired to the light with no overrun, or the moist air just dumps into the loft.
Check the Rules Before You Buy
Approved Document F, the ventilation section of the Building Regulations, sets the minimum extract rate for a bathroom at 15 litres per second when the fan runs intermittently. Check a fan's specification against that figure, not against the headline number printed on the box. The fan also needs a timer or humidity sensor that keeps it running after the light goes off. Electrical work in a bathroom is notifiable under Part P, so either use an electrician registered under a Part P scheme or arrange Building Control sign-off yourself.
A bathroom with no openable window has no real choice here: Approved Document F expects mechanical extract in that room, so the fan is not optional. Even when there is a window, a fan usually does the better job in winter, when the window stays shut and the steam has nowhere to go.
Position the Fan and Route the Duct
Mount the fan high on an external wall, close to the bath or shower but outside the splash zone, and as far from the door as practical so the air crosses the room. Keep the duct as short as you can and use as few bends as possible, because each bend cuts airflow. The duct should fall slightly towards the outside so any condensation drains away rather than pooling inside the pipe. Use 100 mm rigid duct for runs under about three metres, and avoid flexible foil duct, which sags and traps moisture. (That is the single mistake most DIYers make, and it is easy to miss until the first cold morning.)
- Fan rated at 15 litres per second or more for intermittent bathroom use.
- Rigid 100 mm duct, with a fall towards outside.
- Backdraught shutter fitted to the external grille.
- Timer or humidity sensor with a run-on of around 15 minutes after the light is switched off.
Wiring: Where the Electrician Earns the Fee
Zone 1 under BS 7671, the Wiring Regulations, is the space directly above a bath or shower up to 2.25 metres high. Check the fan's IP rating against that zone before you buy, because a fan that is not rated for it will fail early in a damp room. Most DIYers can fit the mounting bracket and run the duct. The connection, the isolator and the test belong to someone on the Part P register, who can self-certify the work and save you a separate Building Control fee. Turn the circuit off at the consumer unit and prove it dead with a voltage tester before touching any terminal.
Cutting the Hole Without Cracking the Tiles
Drill a pilot hole from inside first, and check the cavity with a cable and pipe detector. Plasterboard ceilings are easy. Tiles are not. For a tiled wall, start with a diamond core bit, keep the drill speed low and cool the bit with water. The hole should be slightly larger than the duct so it slides in cleanly, and the gap is sealed with a flexible mastic at the grille. Everything above assumes a standard cavity or a stud wall. If the wall is solid brick with render, core drilling takes much longer and the grille needs a deeper sleeve, which many people underestimate.
Test It Before You Close the Ceiling
Switch the light and the fan on separately, then together. Hold a sheet of tissue against the grille: it should be drawn gently onto the grille within a few seconds. A mirror test works too. Run a hot shower for five minutes, then check whether the bathroom mirror clears within a few minutes after you switch the fan on. If it does not, the duct is undersized, the run is too long, or the grille is blocked by loose insulation. Most failures show up in the last metre of duct, where the backdraught flap has jammed shut.
Expect to pay between £40 and £120 for a decent fan. An electrician will typically charge £150 to £300 for the job if you would rather not do the wiring yourself. Get the duct right and the fan will last for years. Get it wrong and the ceiling shows the damage by the second winter.
Choosing a Fan for a Small Bathroom
A small bathroom is harder to ventilate than a large one, because the air has less room to turn over and a shower fills the space with steam within a minute. Pick a fan with a higher extract rate than the minimum rather than the cheapest one on the shelf. Look at the noise figure too, which is printed on the box. A quiet model gets left running, while a loud one gets switched off after a month and the damp returns. Check the spigot diameter as well, because a mismatch between the fan spigot and the duct cuts real airflow. Keep the fan's instructions in the loft with the duct details, so the next person knows what they are looking at.
The Mistakes That Cost a Second Visit
Most bathroom fans are not replaced because they broke. They are replaced because the first install did not work, and putting it right always costs more than getting it right first time. The first mistake is a duct that ends in the loft: the moist air condenses on the cold timber and soaks the insulation. The second is a grille fitted without a backdraught shutter, so cold air comes back through the fan when the wind blows. The third is a timer set too short, so the fan stops while the room is still steamy. Each one is cheap to avoid and expensive to fix once the plaster is painted. Test the fan before the ceiling is closed up, and you will catch most of them in one go.
If the fan sits between joists that need a bracket, check the joist size before you cut. A fan screwed to plasterboard alone will eventually sag.