Lagging Your Hot Water Cylinder Before the Heating Season: A UK DIY Guide

A cylinder jacket and pipe lagging are among the cheapest winter heating jobs you can do yourself. Here is how to size, fit and test them, and where to stop.

Lagging Your Hot Water Cylinder Before the Heating Season: A UK DIY Guide

Your hot water cylinder is probably the warmest object in the house that nobody looks at. It sits in the airing cupboard or the utility room, holds water usually set around 60°C whether or not anyone runs a bath, and loses heat through its shell all day and all night. Most of that heat never reaches a tap. It warms the cupboard instead, which is pleasant in January and a waste of gas or electricity in every other month. Fitting or topping up a jacket cuts that loss, and it is one of the few heating jobs where the materials are cheap and the risk is low.

Be realistic about the size of the prize. The Centre for Sustainable Energy's hot water cylinder advice gives an upper estimate of up to £194 a year, calculated at October 2025 energy prices. That is a ceiling, not a promise. The saving depends on how poorly insulated the cylinder is to begin with, so a cylinder that already has a good factory foam layer will gain far less than the headline figure. Check your own meter reading before and after, and judge the result against your own bills rather than a leaflet.

Find out what you already have

Before buying anything, look at the cylinder. Many modern cylinders are factory-insulated with a foam layer under a plastic or metal outer skin. If yours is that type, the question is whether the foam is intact and whether the cylinder is tightly enclosed, not whether you can add a thicker blanket. An older cylinder often has a thin, flat, bagged jacket or nothing at all, and that is where the cheap win is.

The Centre for Sustainable Energy advises replacing an existing jacket that is less than 75mm thick or does not fully cover the tank. You will see 80mm quoted often on installer and trade sites, but I could not confirm that figure from the Building Regulations text, so treat it as good practice rather than a legal minimum. Measure the jacket you already own, not the one on the packaging. A jacket that has slumped or been folded double at the top covers a much thinner layer than its label claims.

Buying and sizing the jacket

Measure the cylinder before you go to the shop. Take the height, and the circumference around the widest point, then add a few centimetres to each. Jackets are sold in size bands, and one that is too short leaves the top exposed, which is exactly where the hottest water sits. A jacket that is too tight is hard to fit around the pipework and tends to pull away from the tank as you tighten the straps. Write the measurements on the back of your hand if you have to; it is a much cheaper mistake to avoid than to fix.

Buy a jacket that is labelled for hot water cylinders, with its thickness printed on the packaging. Most builders' merchants and the big DIY chains, including Wickes, B&Q and Screwfix, stock them. Avoid anything sold only as a generic "blanket" with no specification, because you cannot check it against the figures above. I would buy the thicker option when the price difference is small, and I would not buy an unbranded jacket that gives no thickness at all.

Fitting the jacket, step by step

Switch off the immersion heater at the consumer unit before you touch the cylinder. If a boiler heats the cylinder, turn off the heating controls as well, and let the water cool if you need to work near the pipe connections. Once the power is off, the fitting itself carries no electrical risk, and it is a job most people can finish in an afternoon with a tape measure and a pair of scissors. Work slowly, because the jacket is the only thing between you and a scalding splash if a pipe joint gives way.

  • Wrap the jacket around the cylinder, starting at the back, with the seam meeting at the front.
  • Cut openings for the thermostat dial and the immersion switch, and leave them fully accessible; never cover them.
  • Keep the jacket clear of the pipe connections at the top and bottom, and leave the vent or expansion pipe unobstructed.
  • Fasten with the straps or ties supplied, and check that the jacket sits flat at every seam with no gaps.
  • Tuck the top flap down over the cylinder lid without pressing on any joint, then move on to the pipes.

Afterwards, give it a proper test rather than assuming it worked. Put your hand on the cylinder an hour after you turn the heating back on: the outer surface should feel noticeably cooler than before, and the cupboard should stay closer to room temperature. Note the gas or electricity reading on the day you fit the jacket, then compare it after a fortnight of similar weather. Two weeks is short, and the comparison is noisy, but it tells you far more than the box does.

Pipe lagging: do the hot pipes you can reach

Lagging the hot pipes is a separate and smaller job, and the Centre for Sustainable Energy is frank that the savings are modest. Still, pipe lagging is cheap and quick. The pipes that matter most are the ones that run through an unheated loft, a cold garage or along an external wall. Start with the first metre or so leaving the cylinder, then follow the pipe into any cold space. Foam sleeves are the easy option: slide them over the pipe, cut them at a 45-degree angle at elbows, and seal the seams with tape.

Thickness matters more than most people expect. A common trade guide for 15mm and 22mm domestic hot pipes is at least 25mm of closed-cell foam, so check the sleeve against your pipe diameter before you buy. A 13mm sleeve on a 22mm pipe looks neat and does very little. Do not wrap the pipes so tightly that they trap moisture against the wall, and leave every compression joint visible, so that a drip shows up as a drip rather than as a stain on the ceiling below.

Do not confuse the cylinder jacket with lagging the cold water tank in the loft. The cold tank and its feed pipe are the usual freezing risk in a cold snap, and insulating them is a different job with different materials. If the loft is unheated and the tank is exposed, deal with that before the first hard frost, because a split feed pipe will cost far more than any saving on the hot side.

What to leave alone

Some parts of this job are not DIY territory, and the guides tend to go vague at exactly this point. The immersion heater, its thermostat and any wiring belong to a qualified electrician. Do not replace the element, rewire the switch or open the electrical box. Do not assume the immersion is off because the light on its switch has gone out. Isolate it at the consumer unit, and if you cannot confirm which breaker feeds it, stop and call an electrician. The same rule applies to any repair of the cylinder's controls, and a jacket is no reason to start poking at them.

Unvented cylinders need more care again. These sit under mains pressure and carry a temperature and pressure relief valve with a discharge pipe, which must stay clear and visible at all times. Do not wrap the jacket over the valve, its outlet or the discharge route, and do not block the space around them. If a cylinder is leaking from the shell or from a joint, a jacket will not fix it, and the answer is a repair or replacement by a competent installer. A jacket hides a leak until it has become a wet cupboard, so check the base and the pipe joints once a month through the first winter after fitting.

Gas-fired and oil-fired systems add another layer of caution. Keep the jacket away from the boiler flue and any combustion air vents, and never fit anything that restricts airflow to an appliance. If you are unsure about the boiler side of the system, the cylinder jacket can wait until a Gas Safe engineer has checked the installation, and the service visit is a sensible moment to ask about it.

Where the saving is smaller than the sales pitch

The jacket will not fix your bill on its own.

A cylinder that is already well insulated, with a factory foam layer intact, gains little from an extra blanket, and the headline savings quoted by suppliers assume a starting point that many homes do not have. The heating system itself may be a bigger lever than the cylinder: radiators that have never been bled, draughts under doors, and controls that keep the boiler cycling on and off are all common reasons a bill runs high. If the bill is the real worry, check those before you spend a weekend on lagging. Treat the cylinder jacket as one job in a longer list rather than the answer.

I would still fit the jacket, and I would do it before the heating runs hard. It costs little, it takes an afternoon, and it keeps paying for as long as the cylinder stays in service. Fit it at the same time as you check the thermostat, because a cylinder set far above the usual working temperature wastes heat that a jacket cannot recover. Set the thermostat to a sensible level, around 60°C, and read the manufacturer's note on the controls before you change anything, since some systems have a specific setting that must not be altered.